OneLibrary fixture drive
A real OneLibrary USB export, trimmed to the size of a test fixture. This is the
drive test_onelibrary_adapter.py runs against, so the suite needs no USB stick
plugged in and gives the same answer on every machine.
Produced by rekordbox 7.2.18 exporting a two-track playlist to an exFAT stick. Nothing in the database was written or edited by Konduktor — it is the bytes rekordbox itself wrote, which is the whole point of a fixture whose job is to prove we read the real format correctly.
What was changed
Only the analysis files, and only by deleting whole tags:
| File | Original | Here |
|---|---|---|
ANLZ0000.DAT |
4,972 B | 2,812 B |
ANLZ0000.EXT |
85,602 B | 732 B |
PPTH, PQTZ, PCOB and PCO2 — the path, the beatgrid and the two cue lists,
i.e. everything the adapter reads — are kept byte for byte. The waveform tags
(PWAV, PWV2–PWV5) are dropped, which is where ~99% of the .EXT went, and
the .2EX files are omitted entirely.
The trim is byte-level tag surgery, rewriting only the PMAI header's file
length: pyrekordbox cannot rebuild a file containing cue tags, so re-serialising
was not an option.
The two .mp3 files are placeholders, not audio. The adapter resolves paths
and never opens them; carrying 12 MB of demo tracks in the repo to prove that
would be silly.
What is in it
- 2 tracks, one of which (
Demo Track 1) carries a flexible multi-tempo grid (128.00 BPM to 60 s, then 90.00 BPM) — the awkward case, deliberately. - 4 hot cues plus a looped memory cue on that track, including one on pad D,
which is the cue that lives only in the
.EXTand that a reader looking at the.DATalone would lose. - 1 playlist,
demos, holding both tracks in order.
Demo Track 1's title still reads [KONDUKTOR WROTE THIS] because the grid and
title were written into master.db by Konduktor before the export. That is
incidental to the fixture, but it does record that the whole chain — Konduktor →
master.db → rekordbox's OneLibrary export → this file — preserved them.
schema.sql
The complete CREATE TABLE set for a OneLibrary database, all 22 tables,
extracted from Traktor Pro 4.5's binary, which embeds the DDL it uses to create
one. AlphaTheta publishes no specification, so this is the closest thing to one:
a second vendor's independent implementation of the same schema. It was verified
by building an empty database from it and having pyrekordbox's ORM — a third
implementation — open and write to it.
Not loaded by the tests; kept as documentation, and as the starting point if Konduktor ever needs to create a drive from nothing.
rekordbox-edited/
Analysis files from a SECOND stick (Goober), after rekordbox 7 itself edited it
(2026-10-01): a hot cue added on pad E of demo-track-2, and a memory cue added on
the start of nemean's memory loop. Trimmed the same way as above, by dropping
whole tags: only PPTH, PCOB and PCO2 are kept, byte for byte.
They exist for one property: rekordbox writes compact cue entries when it
edits (48 bytes for that hot cue, 44 with no colour for the memory cue; an export
writes 88). pyrekordbox's parser raises on the 44-byte form, which once made the
reader drop the whole .EXT, losing pads D-H and every colour. See
adapters/rekordbox/anlz_file.py.